| Best Option of Hardware Factory Ventilation System |
| Author: Time:2011-12-13 Views:117 |
|
In our impression, the temperature of hardware workshop is very high, even reach 40~45 degrees, sometimes even higher. Although some hardware factory installed high-powered workshop axial flow wind system machine or environmental ventilation system, the muggy and hot still can not be improved. Since the high-powered axial-flow ventilation system or environmental ventilation system can’t solve high temperature problem, according to the traditional mechanical ventilation system design principle to design, re-establishing path of air to make fresh air enter from clean zone and discharge dirty air into outdoor.
 It has the same principle with the central air-conditioning, but central air-conditioning produced refrigerating capacity is far less than hardware needed refrigerating capacity, just a little bit cool in the outlet. But Antarctic hardware factory ventilation system, which is procreative by Antarctic Ventilation Cooling Equipment Co., LTD, uses the principle of air convection and negative pressure ventilation to design. Negative pressure ventilation fan is installed in the poor ventilation place. When normal working, they use mechanical kinetic energy to make exhaust fan operation for emitting the workshop stagnant heat, odor and smoke to outside in the shortest period, and encourage fresh air into hardware workshop at the same time, so as to achieve hardware factory ventilation and cooling.
Negative pressure exhaust fans discharging air to make hardware workshop air pressure drop and air thin for forming a negative pressure zone, and air flows into plant because of pressure difference compensation. In the industrial workshop actual application, negative pressure fans are installed one side of workshop, and the intakes are installed on the other side of workshop. In this process, the doors and windows which close to exhaust fans need to remain closed, for the purpose of forcing air compensation from inlet side to hardware factory. Air flowing from plant to exhaust fans for ensuring hot air, dust and peculiar smell discharge to outlet.
Why the air quality of those hardware factories is still poor even they have been installed large-scale axial flow fans? The reason are as follows. One, The efficiency of axial fans is too low, and its speed only 2800rpm or 1400rpm with high energy consumption, high noise and low efficiency. Two, There is no closed windows, this make exhausted gases returned again. The air is circular motion between fans and windows, so that the air of workshop can not be discharged. In this case, installing Antarctic negative pressure fans is a good choice, which can easily keep hardware factory ventilation and cooling. |
|
|
|